Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Tengen International Industrial Limited
Tengen International Industrial Limited
Home > Residual Current Circuit Breaker >

DZ47LE-32 DZ47LE-63 Combined Residual Current Device 6A 10A 16A 25 32A 40A 50A

Tengen International Industrial Limited
Tengen International Industrial Limited
Province/State: Zhejiang
Country/Region: China
Tel: 86--18657768658
Contact Person:Mr Wang

DZ47LE-32 DZ47LE-63 Combined Residual Current Device 6A 10A 16A 25 32A 40A 50A

Brand Name : Tengen
Model Number : DZ47LE-63G
Certification : GB14048.2
Place of Origin : Zhejiang, China (Mainland)
MOQ : 1
Price : negotiable
Supply Ability : 80000 Pieces per Month
Delivery Time : 8-15 Work Days
Packaging Details : Standard package or according to customer's requirements
Standard : IEC61009-1, GB16917.1
Certificates : CCC
Rated Frequency(Hz) : 50
Frame Size Rate Current(A) Inm : 63
Rated Insulation Voltage(V) Ui : 500
Rated Impulse Withstand Voltage(kV) Uimp : 4
Rated Operation Short-Circuit Breaking Capacity(kA) Ics : 6kA(C6~C40), 4.5kA(C50, C63); 4kA(D Type)
Contact Now

Reliability TGM3L RCCB Industrial Residual Current Circuit Breaker AMPS

1.Product Overview

DZ47LE-63G residual current circuit breaker is suitable for the circuit of AC50/60Hz, 400V rated voltage, 63A rated current. When there is body electric shock or current of grid leakage is over the specified value, the residual current circuit breaker will cut the power in a very short time to protection the body and safety of electric equipment. DZ47LE -63G is also has the protection function of overload, short-circuit, over-voltage, and it also can switch the electric apparatus and illumination circuit frequently. It is quiet applicable for industrial and commercial lighting system.

2.Mode and Meaning



3.Product Parameter

3.1 Main Technical Parameter (Table 1)

Product ModelDZ47LE-63G
StandardIEC61009-1, GB16917.1
CertificatesCCC
Electric Technical
Poles1P+N(N Pole is Connected), 2P, 3P, 3P+N(N Pole is Connected), 4P
Rated Frequency(Hz)50
Frame Size Rate Current(A) Inm63
Rated Current(A) In6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Voltage(V) UeAC230(1P+N, 2P), AC400(3P, 3P+N, 4P)
Rated Insulation Voltage(V) Ui500
Rated Impulse Withstand Voltage(kV) Uimp4
Rated Operation Short-Circuit Breaking Capacity(kA) Ics6kA(C6~C40), 4.5kA(C50, C63); 4kA(D Type)
Rated Short-Circuit Capacity(kA) Icn6kA(C6~C40), 4.5kA(C50, C63); 4kA(D Type)
Rated Residual Connecting Breaking Capacity (A) (I△m)2000
Rated Residual Current Max Breaking Time0.1s
Instant Tripping CharacteristicC, D
Tripping FormThermal Magnetic Trip
Pollution Grade2
Electric and Mechanical AccessoriesOF(Auxiliary), SD(Alarming)
Rated Residual Operation Current(mA) (I△n)30, 50, 100
Mechanical Performance
Electrical Endurance2000
Mechanical Endurance2000
Protection DegreeIP20
Indication Window-
Working Environment
Using Environment-5℃~+40℃
Mounting AltitudeNot over 2000m
Terminal BlockScrew Crimp
Max Connecting Capacity25mm²
Max Ultimate Torque Nm2.5
Mounting TypeⅡ, Ⅲ
Mounting WayTH35-7.5 Type Steel Mounting Rail
Coil-in WayUp Coil-in

3.2 Operation Performance of Over-Current Tripper of Circuit Breaker (Table 2)

Text NumberRated Current In(A)Initial StateTest Current (A)Specified TimeExpected ResultRemark
a6~63Cold State1.13Int≥1hNo Tripping 
b6~63Follow Test a1.45Int<1hTrippingCurrent rise to the specified value within 5s
c6~63Cold State2.55In1s<t<60sTrippingIn≤32A
1s<t<1200sTrippingIn>32A
d6~63Cold State5Int≥0.1sNo TrippingC Type
10Int<0.1sTripping
10Int≥0.1sNo TrippingD Type
20Int<0.1sTripping

Note: the test is taken in the temperature of 30℃~35℃.

3.3 Breaking Time of Residual Current Operation (Table 3)

In (A)I△n (mA)Max (Residual Current) Breaking Time (s)
I△n2I△n5I△n or 250mAᵃ5A-200A, 500Aᵇ
6~6330, 50, 75, 1000.10.080.040.04

Note: a) For I△n≤30mA, RCBO can be replaced by 250mA.
b) In any situation, current which is over the lower limit of current instant tripping range is not
tested.

3.4 Insulating Impulse Withstand Voltage Performance

Impulse voltage between connected poles and neutral pole is 6000V which is the peak value.

Impulse voltage between metal bracket and connected poles with neutral pole is 8000V which is the peak value.

4.Outline and Installation Dimension


  1. Ordering Instruction
    1. Please mark out the following item when ordering:
      1. Product model and name. For example: 63A frame size rated current, and product name is DZ47LE-63G residual current circuit breaker.
      2. Rated current. For example, 40A.
      3. Poles of circuit breaker. For example, 1P+N.
      4. Tripping type. For example, C type.
      5. Rated residual current. For example, 30mA.
      6. Ordering quantity. For example, 50PCS.

  1. Ordering example: DZ47LE-63G residual current circuit breaker, 1P+N, C40, 30mA, 50PCS.

Product Tags:

rccb circuit breaker

      

residual current operated circuit breaker

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

DZ47LE-32 DZ47LE-63 Combined Residual Current Device 6A 10A 16A 25 32A 40A 50A Images

Inquiry Cart 0
Send your message to this supplier
 
From:
To: Tengen International Industrial Limited
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0